Fixed
Beas\Administration\System Initialization
2019-07-19
16310
1
Window position not saved
beas 9.3-001-017-000 / beas 9.3-002-001-000 / beas 9.3H-001-017-000 / beas 9.3H-002-001-000
Beas\Administration\System Initialization
beas - every window:

Previously:
After changing size and position of a window, beas did not save the new position.

Now: Bug Fixed.

Attention:
beas only saves new position if the size is changed, as well.

Beas\Human Resources\Personell
2019-05-02
15675
1
Personnel, Authorization System not working correctly
beas 9.3H-001-018-000 / beas 9.3-001-018-000 / beas 9.3H-002-001-000 / beas 9.3-002-001-000
Beas\Human Resources\Personell > Zendesk id: 65617
Personal Administration / Attendance and Absence

Previous: Editing entries was not possible if the user was not a superuser.
Now: Fixed.

bde_personal_abwzeit_edit.psr, bde_personal_anwesenheitdetail.psr
bde_personal_rglarbzeitendetail.psr
bde_personal_schichtp_edit.psr

Workaround:
replace these 4 psr files from beas 9.3H-001-017-000 
2019-07-19
15473
1
Serial number reservation does not work for supplementarily created sub-assemblies
beas 9.3H-001-018-000 / beas 9.3-001-018-000 / beas 9.3H-002-001-000 / beas 9.3-001-020-000 / beas 9.3H-001-020-000 / beas 9.3-002-001-000
Beas\Production > Zendesk id: 65698
In beas it is possible to reserve serial numbers automatically in a work order if the item is
- administrated by serials
- serial number determination is set to automatic
- in configuration wizard "Production - Valuation and booking - serial number - serial number reservation" is set to "Yes"

Past:
If you inserted a sub-assembly to an existing  work order, there were no serial numbers reserved for the new assembly.
 
Now: When a sub-assembly is inserted, the correct number of serials will be reserved  (if the item is set correct as mentioned above)


 fert_ftstlpos_edit.psr
Beas\Production\Factory data capture\Terminal
2019-05-02
16321
1
Terminal, Accessing beas Basic functionality with Custom Apps/Script
beas 9.3H-001-018-000 / beas 9.3-002-001-000 / beas 9.3-001-018-000 / beas 9.3H-002-001-000
Beas\Production\Factory data capture\Terminal > Zendesk id: 67541

Since the last release you can start beas in terminal mode in a separate instance, once you select it

in the menu "Terminal". There were some problems in the call, because when the terminal
was called fom inside SAP, we could not pass the neccessary password from the logged in User
to the terminal.

Now when the terminal is called from SAP we open the terminal but ask for the password.
Starting from beas standalone we can open the terminal without entering the password.


 

Beas\Usability\beas usability extension (B1UP)
2019-05-02
16311
1
B1UX - function buttons - compatibility with SQL 2008
beas 9.3H-001-017-000 / beas 9.3-002-001-000 / beas 9.3H-002-025-000 / beas 9.3-001-017-000
Beas\Usability\beas usability extension (B1UP) > Zendesk id: 67649
SQL error on editing functions with B1 function package on beas

1. create a new function button
2. click on function list


 
sys_function_browse.psr

1. create a new function button
2. click on function list
2019-05-02
16155
1
Terminal-app Logoff work order: beas crashes if "Attendance Logout" is activated
beas 9.3H-001-017-000 / beas 9.3-002-001-000 / beas 9.3-001-017-000 / beas 9.3H-002-001-000
Beas\WEB > Zendesk id: 67529
When you reported a time receipt and checked the "Attendance Logout" flag, in order to log out the user after writing
the time receipt, a beas error (Systemerror 2: Null object reference...) appeared.
This error only appeared when the setting "Attendance Logoff: automatic logoff work order" was set to true.
The Program is fixed, so this combination of settings will work.


 fert_ftstmp_abmeldung.psr